PENINGKATAN SISTEM SALURAN DRAINASE KAWASAN AIR PUTIH KOTA SAMARINDA PROVINSI KALIMANTAN TIMUR

  • Wahyu Fajar Ramadhan
  • Ratri Andinisari ITN Malang

Abstract

The Air Putih area in Samarinda City regularly experiences flooding with water depths of 30–50 cm lasting up to two hours during high-intensity rainfall events. This flooding results from the inadequate capacity of existing drainage channels to accommodate runoff discharge, sedimentation, and the increasing extent of impervious surfaces due to urban development. This study aims to analyze the layout and capacity of existing drainage channels, calculate the design flood discharge for a 10-year return period, and develop a redesign plan for channels with insufficient capacity. The methods applied include rainfall data consistency testing using the double mass curve, determination of areal rainfall using the Thiessen Polygon method, frequency distribution analysis (Log Pearson Type III and E.J. Gumbel) tested for goodness-of-fit using Chi-Square and Smirnov-Kolmogorov tests, design flood discharge calculation using the Rational Method, and channel redimensioning using Manning's equation. Results show a 10-year design rainfall of 143.83 mm, with existing discharge capacity across 100 channel segments ranging from 0.04–4.96 m³/s and design flood discharge ranging from 0.03–7.77 m³/s. Evaluation revealed that 41 channels meet the required capacity while 59 channels do not, necessitating redesign using rectangular precast U-Ditch sections. This study is expected to serve as a technical reference for local government in addressing flooding issues in the Air Putih area.

Downloads

Download data is not yet available.
Published
2026-11-03