STUDI ALTERNATIF PERENCANAAN STRUKTUR BAJA PADA GEDUNG GKB V UNIVERSITAS MUHAMMADIYAH MALANG DENGAN FLUID VISCOUS DAMPER (FVD)
Abstract
Indonesia is located at the convergence of three major tectonic plates, making it highly vulnerable to earthquakes; therefore, earthquake-resistant structural design is essential. One of the seismic damping devices that can be applied is the Fluid Viscous Damper (FVD), which functions to absorb seismic energy and reduce the design earthquake forces transmitted to structural elements. This study analyzes the performance of a steel structure in the GKB V Building at Universitas Muhammadiyah Malang with the application of three types of FVD, namely 500 kN, 750 kN, and 1000 kN capacity. The structural modeling was carried out using ETABS software, considering dead loads, live loads, and seismic loads in accordance with SNI 1726:2019. The FVDs were installed along the X-axis (longitudinal) and Y-axis (transverse) at the building’s edges. The analysis results indicate that the use of FVDs reduces the structural period, base shear, and inter-story drift, thereby improving the stiffness and stability of the structure. Furthermore, the bending moment in beams decreased, while the axial compressive force and moment in columns increased compared to the structure without FVDs. Overall, the application of FVDs proved effective in enhancing the seismic performance of the structure.